top of page
01 hero.png
FDA-cleared · 510(k)

Paptizer 360

FDA-Cleared
UV-C Light

Wash the cushion, place it in the Paptizer 360, and press start. This FDA-cleared UV-C LED device runs one 30-minute cycle to reduce bacterial populations on your CPAP mask cushion. Ozone-free process, no cartridges,and nothing to reorder.

FDA-cleared

510(k) Class II

99%

in-vitro bacterial reduction*

30 minutes

one cycle, hands off

2-year warranty

on the unit and power supply

*An in vitro 2-log (99%) bacterial reduction has been demonstrated after a complete processing cycle. Tested with ResMed AirFit F20 mask cushions. Any correlation between in vitro results and clinical outcome has not been established.

The Paptizer 360 with its lid closed, plugged in on a kitchen counter beside a plant and u
The Paptizer 360 with its lid closed, plugged in on a kitchen counter beside a plant and u

THE DEVICE

Built for one job, and cleared to do it.

The Paptizer 360 is an FDA-cleared UV-C LED microbial reduction device for single-patient home use. It is intended as an adjunct to reduce bacterial populations on certain compatible home-use CPAP mask cushions after cleaning.

uv-pulse-08-up.jpg

HOW IT WORKS

Four steps, then it runs itself.

Clean it first

Remove the headgear, the frame, and the tubing. Wash the cushion per the mask manufacturer's instructions and let it dry.

One cushion, facing up

Place a single cushion on the quartz glass tray with the opening facing upward, so the LEDs reach the surfaces that touch skin.

Close it and press start

Shut the lid and press START. The LCD counts down thirty minutes. Open the lid at any point and the LEDs cut out.

Leave it alone

When the cycle ends, the unit shuts off. There is nothing to rinse, nothing to wipe, and nothing to reorder. Your mask is ready to use immediately. No product downtime needed.

FEATURES

Five things that set it apart.

40 UV-C LEDs

260 to 280 nm, rated for up to a 10,000-hour lifespan. LEDs, so there's no lamp or filters to change.

Thirty-minute cycle

An LCD counts it down, then the unit shuts itself off. Four buttons: ON, START, PAUSE, OFF.

Six species commonly found on CPAP masks, laboratory tested

S. aureus , S. epidermidis , P. aeruginosa , K. pneumoniae , S. pyogenes , and E.coli , tested with the ResMed AirFit F20 cushion. Full log-reduction data below. 

Lid safety sensor

Open the lid mid-cycle and the LEDs cut out. No UV-C exposure to eyes or skin.

Quartz glass tray

A special quartz-glass blend lets UV-C light pass through the tray for full 360-degree microbial reduction around the cushion.

THE METHOD

Forty UV-C LEDs emit at 260–280 nm. Light does the work, in an ozone-free process.

The LEDs are rated for up to 10,000 hours. Nothing wears out on a schedule, so there is no consumable and no subscription.

Ozone-free process
No consumables
Component 9.png
Component 9.png

SPECIFICATIONS

The whole spec sheet.

Power input

Connector

Light source

LED life

Dimensions

Weight

Cycle

18 V / 1.5 A, 27 W

USB Type-C

40 UV-C LEDs, 260–280 nm

Up to 10,000 hours

11.89 × 10.59 × 6.06 in 302 × 269 × 154 mm

4.975 lb with tray 4.069 lb unit, 0.906 lb tray

30 minutes, automatic shut-off

Operating temperature

Storage temperature

Humidity

Emissions

Use

Warranty

Service life

41–104 °F

13–158 °F

15–90 %

Group 1, Class B

Adult, single-patient, one cushion per cycle

2 years unit and power supply 30 days quartz tray

Discontinue use after 5 years

In the box

✓ Paptizer 360 unit

✓ Power supply

✓ Quartz glass tray

✓ Suction cup for lifting the tray

✓ User manual

THE DEVICE

Protections, built in.

Clear limits and safeguards, taken straight from the device labeling.

Eyes and skin

No UV-C exposure while it runs

Power

Keep plugged in for the full cycle

Keep it dry

Away from water and liquids

Who it's for

Adults, single-patient home use

Service life

Discontinue after five years

THE DATA

What the lab actually found.

Log reduction measured in vitro on production units.

Any correlation between in vitro results and clinical outcome has not been established. This device must not be used to replace the cleaning procedures as recommended by the CPAP mask manufacturers.

Testing performed on new Paptizer 360 production units (25A series) using ResMed AirFit F20 mask cushions.

cta-units.webp

FOR BUSINESS

Add the Paptizer 360 to your line.

We supply DMEs, sleep clinics, CPAP retailers, and distributors. Tell us what you stock and where you sell, and we will come back to you with the trade terms.

FAQ

Frequently asked questions.

__before.png
__before.png

THE DEVICE

Talk to a person.

General inquiries

info@liviliti.com or +18889870744

Warranty registration

Register your Paptizer 360

Fill in your details and we'll get back to you.
bottom of page